Apc Back Ups Cs 500 User Manual

  1. Apc Back-ups Cs 500 Service Manual
  2. Apc Back Ups 350 Manual
  3. Apc Back-ups Es 500 Service Manual
  4. Apc Back-ups Es 500 Manual
  5. Apc Ups Es 500 Manual
  6. Apc Back Ups Es 500 User Manual
  7. Apc Back Ups 600 Manual

APC Back-UPS CS 500 APC Back-UPS CS, 500VA/300W, Input 120V/Output 120V, Interface Port DB-9 RS-232, USB. Includes: CD with software, Cord Management Straps, USB cable, User Manual.

Page 2: Troubleshooting, Specifications, Back-ups storage, Order replacement battery, Transfer voltage adjustment (optional)

Advertising

Back-UPS does not power computer/monitor/external drive during an outage

  1. APC Back-UPS 500 CS (BK500) offers the best value for protecting your home and home office computer systems, providing battery backup power that allows you to work through short and medium length power outages. It also safeguards your equipment from damaging surges and spikes that travel along your utility and phone lines. Specifications for APC Back-UPS 500 CS.
  2. Aug 05, 2013  Buy APC BK500BLK Back-UPS Cs 500VA/300W UPS System, Gray: Uninterruptible Power Supply (UPS) - Amazon.com FREE DELIVERY possible on eligible purchases.

Internal battery is not connected.

Computer, monitor or external disk/

CD-ROM drive is plugged into a

Surge Only outlet.

Check the battery connections. (See “Connect the Battery” under

“Installation” on the front page of this document.

Move computer, monitor, or external drive power cord plug to the

Battery Backup outlets.

Back-UPS operates on battery although normal utility voltage exists

Back-UPS circuit breaker “tripped”.

The wall outlet that the Back-UPS is

connected to does not supply utility

power to the unit.

Disconnect non-essential equipment from the

Back-UPS. Reset the circuit breaker (located

on the rear panel of the Back-UPS) by push-

ing the circuit breaker button fully inward

until it catches.

Back-UPS does not provide expected backup time

Back-UPS is excessively loaded.

Back-UPS battery is weak due to

recent outage and has not had time

to recharge.

500

Battery requires replacement.

Unplug non-essential Battery Backup connected equipment, such as

printers and plug them into Surge Only outlets.

Note: Devices that have motors or dimmer switches (laser printers,

heaters, fans, lamps, and vacuum cleaners, for example) should not be

connected to the Battery Backup outlets.

Charge the battery. The battery charges whenever the Back-UPS is

connected to a wall outlet. Typically, eight hours of charging time are

needed to fully charge the battery from total discharge. Back-UPS

run-time is reduced until the battery is fully charged.

Replace battery (see Order Replacement Battery). Batteries typically

last 3-6 years, shorter if subjected to frequent power outages or ele-

vated temperatures.

A red indicator is lit

Battery is not connected properly.

The Overload indicator is lit if

equipment connected to the Battery

Backup outlets is drawing more

power than the Back-UPS can pro-

vide.

Battery requires replacement.

Check the battery connections. Consult 'Connect the Battery' under

'Installation' on the front page of this document. It shows how to

access the battery and connect the wires.

Move one or more equipment power plugs to the Surge Only outlets.

The battery should be replaced within two weeks (see 'Order

Replacement Battery'). Failure to replace the battery will result in

reduced run-time during a power outage.

Connect the Back-UPS to another wall outlet or have a qualified

electrician check the building wiring.

Red indicators are flashing

Back-UPS failure.

Call APC for service.

Service

1.

Consult the Troubleshooting section to eliminate common problems.

2.

Determine if the circuit breaker is tripped. If the circuit breaker is tripped, reset the breaker and
determine if the problem still exists.

3.

If the problem persists, consult the APC Worldwide Web site (www.apcc.com) or call customer
service.

Record the model number of the UPS, the serial number, and the date purchased. Be prepared
to troubleshoot the problem over the telephone with a technician. If this is not successful, the
technician will issue a Return Merchandise Authorization Number (RMA#) and a shipping
address.

If the UPS is under warranty, repairs are free. If not, there is a repair charge.

4.

Pack the UPS in its original packaging. If the original packing is not available, ask customer ser-
vice about obtaining a new set. Pack the UPS properly to avoid damage in transit.

5.

Write the RMA# on the outside of the package.

6.

Return the UPS by insured, prepaid carrier to the address provided by customer service.

Note: If the UPS requires service, do not return it to the dealer. The following steps should
be taken:

Note: Never use Styrofoam

TM

beads for packaging. Damage sustained in transit is

not covered under warranty (insuring the package for full value is recommended).

Warranty

The standard warranty is two (2) years from the date of purchase. APC’s standard procedure is to replace

the original unit with a factory reconditioned unit. Customers who must have the original unit back due

to assigned asset tags and set depreciation schedules must declare such a need at first contact with an

APC Technical Support representative. APC will ship the replacement unit once the defective unit has

been received by the repair department, or cross ship upon the receipt of a valid credit card number. The

customer pays for shipping the unit to APC. APC pays ground freight transportation costs to ship the

replacement to the customer.

APC Contact Information

Replace Battery indicator lit and an alarm sounds when the Back-UPS is turned on

Internal battery not connected.

Check the battery connections.

Copyright © 2000 American Power Conversion. All rights reserved.

USA/Canada

Mexico

Brazil

Worldwide

Internet

Technical Support

1.800.800.4272

292.0253 / 292.0255

0800.12.72.1

1.401.789.5735

http:www.apc.com

http:www.apc.com/support

Troubleshooting

Use the tables below to solve minor Back-UPS installation and operation problems. Consult APC On-line

Technical Support or call APC Technical Support for assistance with problems that cannot be resolved using

Apc Back-ups Cs 500 Service Manual

this document:

Possible Cause

Procedure

Back-UPS will not switch on

Back-UPS not connected to an AC

power source.

Back-UPS circuit breaker “tripped”.

Very low or no utility voltage.

Check that the Back-UPS power plug is

securely connected to the wall outlet.

Disconnect non-essential equipment from the

Back-UPS. Reset the circuit breaker (located

on the rear panel of the Back-UPS) by push-

ing the circuit breaker button fully inward

until it catches. If the circuit breaker resets,

switch the Back-UPS on and reconnect the

equipment one-at-a-time. If the circuit

breaker trips again, it is likely that one of the

connected devices is causing the overload.

Check the wall outlet that supplies power to

the Back-UPS using a table lamp. If the lamp

bulb is very dim, have the utility voltage

checked by a qualified electrician.

180 - 264 Vac (default setting)

47 - 63 Hz (autosensing)

Stepped Sine Wave

350 VA - 210 W 500 VA - 300 W

8 Hours

0

o

to 40

o

C (32

o

to 104

o

F)

-5

o

to 45

o

C (23

o

to 113

o

F)

0 to 95% non-condensing

16.5 x 9.2 x 28.5 cm (6.5 x 3.6 x 11.2 inches)

350 VA - 6.3 kg (13.8 lbs) 500 VA - 13.8 lb (6.3 kg)

350 VA - 7.0 kg (15.3 kg) 500 VA - 15.3 lb (7.0 kg)

EN 55022, IEC 801-2 and 801-4 (level IV), and IEC 801-3 (level III)

20 Minutes typical - desktop computer and 15 inch (38.1 cm) monitor.

Specifications

Input Voltage (on line)

Frequency Limits (on line)

On Battery Waveshape

Maximum Load

Typical Recharge Time

Operating Temperature

Storage Temperature

Operating and Storage

Relative Humidity

Size (H x W x D)

Weight

Shipping Weight

EMI Classification

On Battery Run-Time

Back-UPS Storage

Before storing, charge the Back-UPS for at least eight hours. Store the Back-UPS covered and upright in

a cool, dry location. During storage, recharge the battery in accordance with the following table:

Please contact APC Technical Support to troubleshoot the unit before returning it to APC.

Storage Temperature Recharge Frequency Charging Duration

-5

o

to 30

o

C (23

o

to 86

o

F)

30

o

to 45

o

C (86

Apc Back Ups 350 Manual

o

to 113

o

F)

Every 6 months

Every 3 months

8 hours

8 hours

Order Replacement Battery

The typical battery lifetime is 3-6 years (depending on the number of discharge cycles and operating

temperature). A replacement battery can be ordered over the phone from APC, or the battery can be ordered

on-line from the APC web site (see below, a valid credit card is required).

When ordering, please specify Battery Cartridge RBC2.

Transfer Voltage Adjustment (optional)

In situations where the Back-UPS or connected equipment appears too sensitive to input voltage, it may

be necessary to adjust the transfer voltage. This is a simple task requiring use of the front panel

pushbutton. To adjust the transfer voltage, proceed as follows:
1. Plug the Back-UPS into the utility power source. The Back-UPS will be in a Standby Mode (no

indicators lit).

2. Press the front panel pushbutton fully inward for 10 seconds. All indicators on the Back-UPS will

flash to acknowledge going into Programming Mode.

3. The Back-UPS will then indicate its current Lower Transfer Voltage, as shown in the following table.

4. To select 160 volts as the Lower Transfer Voltage, press the pushbutton until 1 indicator is flashing.
5. To select 180 volts as the Lower Transfer Voltage, press the pushbutton until 2 indicators are flashing.
6. To select 196 volts as the Lower Transfer Voltage, press the pushbutton until 3 indicators are flashing.
7. Once in Programming Mode, if the pushbutton is not pressed within 5 seconds, the Back-UPS will

exit the Programming Mode, and all indicators will extinguish.

Indicators Lit

Lower Transfer Voltage

Use When

1

2
3

160 VAC

180 VAC (factory default)

196 VAC

Back-UPS frequently goes On Battery due to

Normal power conditions exist.

Connected equipment is sensitive to low voltage.

low input voltage.

1

2 3

4

5 6

7

8 9
0

*

#

Advertising
This manual is related to the following products:

Apc Back-ups Es 500 Service Manual

Popular Brands
Popular manuals

Includes: CD with software, Cord Management Straps, USB cable, User Manual

#BK500
Our Price: $119.00

The re-invention of the most relied upon desktop UPS in history: the Back-UPS!

The Back-UPS CS offers our best value for protecting your business and office computer systems. It provides battery backup power that allows you to work through short and medium length power outages. It also safeguards your equipment from damaging surges and spikes that travel along your utility and phone lines. Award-winning shutdown software automatically powers down your computer system in the event of an extended power outage. Additional features like Audible alarms, LED status indicators, user replaceable battery, push-button circuit breakers and Transformer-block spaced outlets make the Back-UPS CS the perfect unit to protect your business' productivity from the constant threat of power outages and lost data.

Features & Benefits:

Protection
Battery-protected and surge-only outletsReserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment
Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.
Dataline Surge ProtectionProvides protection of connected equipment from power surges on the data lines.
Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals.
Convenience
Audible alarmsProvides notification of changing utility power and UPS conditions.
Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.
Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery replacement without toolsProvides reduced risk of load disruption by allowing quick and easy battery replacement.
LED status indicatorsQuickly understand UPS status with indicators.
Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replaced
Resettable circuit breakersEnables quick recovery from UPS overload events.
Transformer-block spaced outletsProtect equipment with input transformer blocks without blocking access to other receptacles.
User-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Runtime Chart:

Apc Back-ups Es 500 Manual

120V
Watts50100200300400500600700800FullHalf
VA~8016032048064080096011201280LoadLoad
BK35047 min19 min5 min------5 min (210 Watts)18 min (105 Watts)
BK5001 hrs 2 mins26 min8 min2 min-----2 min (300 Watts)14 min (150 Watts)
BK500BLK1 hrs 2 mins26 min8 min2 min-----2 min (300 Watts)14 min (150 Watts)

Technical Specifications:

Output
Output Power Capacity300 Watts / 500 VA
Max Configurable Power300 Watts / 500 VA
Nominal Output Voltage120V
Waveform TypeStepped approximation to a sinewave
Output Connections(3) NEMA 5-15R (Battery Backup)
(3) NEMA 5-15R (Surge Protection)
Input
Nominal Input Voltage120V
Input Frequency50/60 Hz +/- 3 Hz (auto sensing)
Input ConnectionsNEMA 5-15P
Cord Length6 feet (1.83 meters)
Input voltage range for main operations98 - 140V
Batteries & Runtime
Battery TypeMaintenance-free sealed Lead-Acid battery with suspended electrolyte: leakproof
Typical recharge time8 hour(s)
Replacement battery cartridgeRBC2
RBC™ Quantity1
Typical Backup Time at Half Load13.9 minutes (150 Watts)
Typical Backup Time at Full Load2.4 minutes (300 Watts)
Runtime ChartBack-UPS CS
Communications & Management
Interface Port(s)USB
Control PanelLED status display with On Line : On Battery : Replace Battery and Overload indicators
Audible AlarmAlarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering
Surge Energy Rating480 Joules
FilteringFull time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449
Dataline ProtectionRJ-11 Modem/Fax/DSL protection (two wire single line)
Physical
Maximum Height6.50 inches (165 mm)
Maximum Width3.60 inches (91 mm)
Maximum Depth11.20 inches (284 mm)
Net Weight13.80 lbs. (6.27 kg)
Shipping Weight15.30 lbs. (6.95 kg)
Shipping Height10.35 inches (263 mm)
Shipping Width6.89 inches (175 mm)
Shipping Depth14.06 inches (357 mm)
Master Carton Units2.00
Master Carton Weight31.50 lbs.
ColorWhite
SCC Codes107 31304 02136 7
Units per Pallet80.00
Environmental
Operating Environment32 - 104°F (0 - 40°C)
Operating Relative Humidity0 - 95%
Operating Elevation0-10000 feet (0-3000 meters)
Storage Temperature5 - 113°F (-15 - 45°C)
Storage Relative Humidity0 - 95%
Storage Elevation0-50000 feet (0-15000 meters)
Audible noise at 1 meter from surface of unit45.00 dBA
Online Thermal Dissipation24.00 BTU/hr
Conformance
Regulatory ApprovalsFCC Part 15 Class B,Industry Canada,UL 1778,cUL Listed
Standard Warranty3 years repair or replace
Equipment protection policyLifetime: $25,000
**The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS.

Documentation:

Download the APC BK500 Data Sheet (PDF).

Pricing Notes:

  • Pricing and product availability subject to change without notice.
  • Note: Shipping charges may vary depending on the selected unit's weight or the quantity of units selected. As a result, the shipping charges may change from the value you receive at checkout. A customer representative will confirm these changes with you if they occur before processing your order.

Apc Ups Es 500 Manual

#BK500
Our Price: $119.00
Cables
#AP9827
Our Price: $34.00

Apc Back Ups Es 500 User Manual

APC NetBotz USB Latching Repeater Cable, LSZH - 5m
APC NetBotz USB Latching Repeater Cable, Plenum - 5m
#NBAC0214L
Our Price: $44.00
#NBAC0214P
Our Price: $59.00
Extended Warranty & Service Agreements

Apc Back Ups 600 Manual

Please Note: Extended Warranties must be purchased before the termination date of the original factory warranty, Extended Warranties are non transferable. Some aspects of the service definition presented on this web site may vary by location. In the case of a conflict between the service definitions contained on this site and the local service definitions the local service definitions will prevail. For more information, please visit our services page.
Service Pack 1 Year Extended Warranty (for concurrent sales)
Service Pack 3 Year Extended Warranty (for concurrent sales)
#WEXTWAR1YR-SP-01
Our Price: $44.00
#WEXTWAR3YR-SP-01
Our Price: $89.00