Red Lion 306a Display User Manual

Model pax - 1/8 din digital input panel meters, Cus listed, General description

  1. Red Lion Display Manual
  2. Red Lion User Manual
Advertising

Red Lion PAXLA User Manual. Pax lite dc volt/current/process meter. 1/8 din analog input panel meters, process, voltage, current, and temperature inputs, 5-digit 0.56' high led display, programmable function keys/user input, 9 digit totalizer integrator with batching, optional custom units overlay w/backlight, nema 4x/ip6 (20 pages). Model paxp - 1/8 din process input panel meter DIMENSIONS “In inches (mm)” Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.1' (53.4) H x 5' (127) W.

1

COUNT, DUAL COUNTER, RATE AND SLAVE DISPLAY

0.56' RED SUNLIGHT READABLE DISPLAY

VARIABLE INTENSITY DISPLAY

10 POINT SCALING FOR NON-LINEAR PROCESSES (PAXI)

Red Lion Display Manual

FOUR SETPOINT ALARM OUTPUTS (W/Option Card)

RETRANSMITTED ANALOG OUTPUT (W/Option Card) (PAXI)

COMMUNICATION AND BUS CAPABILITIES (W/Option Card) (PAXI)

BUS CAPABILITIES; DEVICENET, MODBUS, AND PROFIBUS-DP

CRIMSON

®

PROGRAMMING SOFTWARE (PAXI)

ETHERNET(W/ External Gateway) (PAXI)

NEMA 4X/IP65 SEALED FRONT BEZEL

GENERAL DESCRIPTION

The PAX Digital Input Panel Meters offer many features and performance

capabilities to suit a wide range of industrial applications. Available in three

different models, PAXC Counter/Dual Counter, PAXR Rate Meter and the PAXI

which offers both counting and rate in the same package. Refer to pages 4 - 5 for

the details on the specific models. The PAXC and PAXR offer only the Setpoint

Option, while the PAXI is the fully featured version offering all the capabilities

as outlined in this bulletin as well as a slave display feature. The optional plug-in

output cards allow the opportunity to configure the meter for present applications,

while providing easy upgrades for future needs.

The meters employ a bright 0.56' LED display. The meters are available with

a red sunlight readable or standard green LED display. The intensity of the

display can be adjusted from dark room applications up to sunlight readable,

making it ideal for viewing in bright light applications.

The meters accept digital inputs from a variety of sources including switch

contacts, outputs from CMOS or TTL circuits, magnetic pickups and all

standard RLC sensors. The meter can accept directional, uni-directional or

Quadrature signals simultaneously. The maximum input signal varies up to 34

KHz depending on the count mode and function configurations programmed.

Each input signal can be independently scaled to various process values.

The Rate Meters provide a MAX and MIN reading memory with programmable

Red lion user manual

capture time. The capture time is used to prevent detection of false max or min

readings which may occur during start-up or unusual process events.

The meters have four setpoint outputs, implemented on Plug-in option cards.

The Plug-in cards provide dual FORM-C relays (5A), quad FORM-A (3A), or

either quad sinking or quad sourcing open collector logic outputs. The setpoint

alarms can be configured to suit a variety of control and alarm requirements.

Communication and Bus Capabilities are also available as option cards for

the PAXI only. These include RS232, RS485, Modbus, DeviceNet, and

Profibus-DP. Readout values and setpoint alarm values can be controlled

through the bus. Additionally, the meters have a feature that allows a remote

computer to directly control the outputs of the meter. With an RS232 or RS485

card installed, it is possible to configure the meter using Red Lion’s Crimson

software. The configuration data can be saved to a file for later recall.

A linear DC output signal is available as an optional Plug-in card for the PAXI

only. The card provides either 20 mA or 10 V signals. The output can be scaled

independent of the input range and can track any of the counter or rate displays.

Once the meters have been initially configured, the parameter list may be

locked out from further modification in its entirety or only the setpoint values

can be made accessible.

The meters have been specifically designed for harsh industrial environments.

With NEMA 4X/IP65 sealed bezel and extensive testing of noise effects to CE

requirements, the meter provides a tough yet reliable application solution.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in this

literature or on equipment must be observed to ensure personal safety and to

prevent damage to either the instrument or equipment connected to it. If

equipment is used in a manner not specified by the manufacturer, the protection

provided by the equipment may be impaired.

Do not use this meter to directly command motors, valves, or other actuators

not equipped with safeguards. To do so can be potentially harmful to persons or

equipment in the event of a fault to the meter.

MODEL PAX - 1/8 DIN DIGITAL INPUT PANEL METERS

Bulletin No. PAXICR-C
Drawing No. LP0896
Released 10/12

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

CAUTION: Risk of Danger.

Read complete instructions prior to

installation and operation of the unit.

CAUTION: Risk of electric shock.

3.80

1.95

.10

4.10

(2.5)

(96.5)

(49.5)

(104.1)

1.75

(44.5)

RST

DSP

PAR

F1

F2

A

C

B

SP1

SP3

SP2

SP4

8.8.8.8.8.8

3.60 (91.4)

25

24

23

22

21

20

3

2

1

6

5

4

8

7

11

10

9

15

14

13

19

18

17

12

16

(44.5)

1.75

DIMENSIONS In inches (mm)

Note: Recommended minimum clearance (behind the panel) for

mounting clip installation is 2.1' (53.4) H x 5' (127) W.

C

US LISTED

UL

R

51EB

Red Lion User Manual

IND. CONT. EQ.

Advertising
This manual is related to the following products:
Popular Brands
Popular manuals